Description
The Danner Replacement Impeller for Model 18 pumps (Danner item 12776) is the impeller and magnet assembly for Danner’s 1,800 GPH Mag-Drive pumps: the Pondmaster Pond-Mag PM 1800 (item 02728), the Supreme Aqua-Mag Model 18 (item 02718) and the Supreme Hydro-Mag Model 18 with Venturi (item 40138). Danner says a worn or broken impeller assembly should be replaced as a whole, and that doing so restores the pump to its original capacity.
Specs
| Danner item number | 12776 |
|---|---|
| Danner part name | Replacement Impeller for Model 18 02718, 02728 or 40138 |
| Fits (as Danner lists them) | Supreme Aqua-Mag Magnetic Drive Water Pumps (Model 18) (#02718); Pondmaster Pond-Mag Magnetic Drive Water Pumps (PM 1800) (#02728); Supreme Hydro-Mag Recirculating Water Pumps (Model 18 with Venturi) (#40138) |
| Pump size | 1,800 GPH |
| Part type | Impeller and magnet assembly |
| Danner catalog listing | Impeller/Mag for Pump Model 18 (B), item 12776 |
| Model number location | Printed on the pump or on the label near the cord |
| Danner manual | ZG100, Care and Operating Instructions for 9.5, 12 and 18 Mag-Drive pumps |
Which size do I need?
Check the rating label on your pump for its model, then match it here. Danner’s parts lists pair each Mag-Drive model with its impeller:
- Model 1.9 (190 GPH Fountain-Mag, Hydro-Mag Model 1.9): Danner 12955
- Model 2 (PM 250, Aqua-Mag Model 2, Hydro-Mag Model 2): Danner 12555
- Model 3 and Model 5 (PM 350, PM 500, Aqua-Mag Models 3 and 5, Hydro-Mag Models 3 and 5): Danner 12575
- Model 7 (PM 700, Aqua-Mag Model 7, Hydro-Mag Model 7): Danner 12585
- Model 9.5 (PM 950, Aqua-Mag Model 9.5, Hydro-Mag Model 9.5): Danner 12746
- Model 12 (PM 1200, Aqua-Mag Model 12, Hydro-Mag Model 12): Danner 12756
- Model 18 (PM 1800, Aqua-Mag Model 18, Hydro-Mag Model 18): Danner 12776, this part
How to use it
- Rule out debris first. Danner lists debris caught inside the volute as a cause of noise, and debris in the inlet or around the center hub as a cause of slow pumping. A broken ceramic shaft, key or impeller blade is different: Danner says to replace the entire impeller assembly.
- Disconnect power to the pump and lift it out of the water.
- Take off the volute, which is the pump cover, to reach the impeller assembly.
- Pull the old impeller assembly out of the pump body and set the new one in its place. Danner calls the impeller the only serviceable item in the pump.
- Refit the volute. To start, the pump has to sit below water level and be full of water, and air has to be able to escape from the outlet.
- Never run it dry. Danner says Mag-Drive pumps need water in the rotor chamber and will overheat and seize without it.
Works well with
- Danner Pondmaster Pond-Mag 1800 GPH Pump: Danner lists this impeller for the PM 1800 (item 02728).
- Danner Replacement Volute for 1200 and 1800 GPH Pumps: Danner’s pump cover for Model 12B and 18 pumps, the part you take off to reach the impeller.
- Danner Foam Pre-Filter for Model 9.5, 12 and 18 Pumps: Danner’s foam pre-filter for its 950, 1200 and 1800 GPH Mag-Drive pumps.
Common questions
How do I find my pump’s model number? Danner says it is printed directly on the pump or on the label near the electrical cord. Look for the rating label on the body of the pump, or check the model number on your receipt, then match it to the list above.
Does it come with the magnet? Yes. Danner’s 2026 catalog lists item 12776 as the “Impeller/Mag” for Pump Model 18 (B). If the ceramic shaft inside your old impeller broke, Danner says to replace the entire impeller assembly right away, before it damages the magnet and the inside of the pump. Ceramic is hard but brittle, and Danner says the shaft usually breaks when a pump gets dropped.
How do I keep scale off the new impeller? Danner says to clean the pump periodically with Danner PumpGuard: disconnect power, take the pump out, turn the volute inlet up, fill it with PumpGuard, let it soak 2 to 3 minutes and rinse with clean water. For pumps used in salt water or hard water, Danner says the magnet impeller assembly must be removed and cleaned in white vinegar at least once every three months, or more often if your water calls for it: pull the magnet and impeller apart (it may take a strong pull), soak the magnet in white vinegar for a few hours and scrape the scale off the shaft and bearing inside it. Do not lose the washers between the end cap and the impeller when you put it back together. Danner says not to take the impeller apart except for this salt water or hard water cleaning.
Questions? Call the shop at (305) 850-9949.
See more in Parts and Accessories.
Shipping & Returns
- Equipment and dry goods ship at their own rate. Free shipping at $299 or more applies to qualifying livestock only — corals, fish, inverts and live copepods. The $5 Box & Handling Fee is a livestock packing fee and does not apply to dry-goods orders.
- All sales are final on equipment and dry goods. We are a retail store, not the manufacturer.
- Register your product with the manufacturer and keep your receipt — their warranty is how a faulty unit gets replaced, and they are faster at it than a shop could be.
- Not sure who to contact for a warranty claim? Call us and we will point you to the right place.
Questions? Call (305) 850-9949










Reviews
There are no reviews yet.